Overview |
|
The RAEGuard LEL
is a permanently mounted (fixed)
catalytic bead combustible gas
detector/transmitter that operates
from a 9 to 36 VDC power source and
provides an analog (4 to 20mA) and
digital (RS-485) signal output in
the range of 0 to 100%LEL
combustible gas. Housed in an
explosion-proof enclosure, the
RAEGuard LEL is equipped with a
local digital display of the gas
concentration and function keys for
performing calibration. The RAEGuard
LEL can be operated with a standard
4 to 20mA/RS-485 controller or as a
stand-alone sensor module.
Fixed Combustible Gas Monitor, 4 to
20mA/RS-485 Transmitter |
|
|
|
Key
Feature |
-
Highly
poison-resistant
catalytic bead
combustible gas LEL
sensor
-
4 to
20mA analog and RS-485
digital output of 0 to
100%LEL combustible gas
including methane,
hydrogen or other
combustible gases
-
Explosion-proof
enclosure for hazardous
environment applications
Local displays with
adjustment keys
-
Non-intrusive
calibration
-
Magnetic
key interface eliminates
need to open
explosion-proof housing
when making calibrations
or other minor
adjustments
Operation at 9 to 36 VDC
-
Dry-contact output
(<30V, 2A)
Hazardous
Location Classification
-
UL:
Class I, Division 1,
Groups B, C, D
-
Temperature Code T6
-
Chinese
Certificate: Ex d IICT6
|
|
|