Size |
235mm L x 127mm W x 235mm D without handle |
|
Weight |
13.85 lbs (6.3 kg) with battery pack |
|
Detector |
Up to five sensors (O2, combustible, two toxic and VOC), electrochemical sensors for toxic gases and oxygen, photoionization sensor for VOC, catalytic combustion sensor for combustible gases |
|
Battery |
Rechargeable Lithium-ion battery (to be charged outside the instrument) |
|
Operating Hours |
18 hrs continuous wireless operation (Lithium-ion battery) |
|
Displays |
2-line, 16-digit LCD with manually activated LED back light |
|
Keypads |
3 operation and 4 programming keys |
|
Direct Readout |
Instantaneous values, sensor name, high and low values for all detectors, TWA and STEL values for toxic gases and VOCs, battery voltage and elapsed time |
|
Alarm |
Flashing red LED cluster to indicate exceeded preset limits, low battery or sensor failure |
|
Alarm Setting |
Separate alarm limit settings for TWA, STEL,Low and High alarm |
|
Audible Alarm |
Buzzer, 100dB buzzer at 10cm (typical) |
|
Visual Alarm |
Flashing red LED cluster |
|
Alarm Mode |
Latching/automatic reset |
|
4,000 points for each sensor with time stamp, serial number, user ID, site ID |
|
|
20,000 readings (64 hours, 5 channels at 1 minute intervals) in non-volatile memory |
|
Datalog Interval |
Programmable 1 to 3,600 sec |
|
Communication |
Upload data to PC and Download monitor setup from PC through RS-232 link to serial port on PC |
|
EM Immunity |
No effect when exposed to 0.43 mW/cm2 RF interference (5-watt transmitter at 30cm) |
|
Safety Certification |
Europe: ATEX II 2G EEx ib d IIc T4 (w/869 Mhz modem) |
|
Frequency |
869 MHz (License-free) |
|
RF Range |
Up to 3 km |
|
Error Detection |
32 bit CRC, resend on error |
|
Callibration |
Two-point field calibration for fresh air and standard reference gas |
|
Sampling Pump |
Internal integrated diaphragm pump with programmable High (400cc/min) and Low (300cc/min) flow rate settings |
|
Low Flow Alarm |
Auto shutoff pump at low-flow condition |
|
Temperature |
-20° to 45° C (-4° to 113° F) |
|
Humidity |
0% to 95% relative humidity (non-condensing) |
|
Attachment |